<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>PP air Ducts &#8211; XICHENG PP DUCT</title>
	<atom:link href="https://plastic-duct.com/product-tag/pp-air-ducts/feed/" rel="self" type="application/rss+xml" />
	<link>https://plastic-duct.com</link>
	<description>Polypropylene PP air duct manufacturers</description>
	<lastBuildDate>Fri, 04 Sep 2026 02:00:54 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.4</generator>

<image>
	<url>https://plastic-duct.com/wp-content/uploads/2022/03/cropped-xicheng-logo-32x32.png</url>
	<title>PP air Ducts &#8211; XICHENG PP DUCT</title>
	<link>https://plastic-duct.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Polypropylene Rectangular Ducts</title>
		<link>https://plastic-duct.com/product/polypropylene-rectangular-ducts/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=polypropylene-rectangular-ducts</link>
		
		<dc:creator><![CDATA[Corbin – Engineer]]></dc:creator>
		<pubDate>Wed, 15 Mar 2023 06:58:08 +0000</pubDate>
				<guid isPermaLink="false">https://plastic-duct.com/?post_type=product&#038;p=2809</guid>

					<description><![CDATA[<p>This polypropylene (PP) rectangular duct is a square-section air duct made to order from PP sheet welding, in standard PP or flame retardant PPs, in beige or grey, with collar or flange connections, in 3 m sections or custom lengths. It suits duct runs where a square section fits the space or matches laboratory and industrial equipment connections.</p>
<ul>
  <li>Made to order: width, height, wall thickness and length confirmed per project</li>
  <li>Standard PP or flame retardant PPs; beige or grey</li>
  <li>Collar or flange connection; 3 m or custom length</li>
  <li>PP sheet-welded with flange welding reinforcement</li>
  <li>Corrosion resistant (pH 1-14), sound insulating, anti-condensation</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h2>Product Overview</h2>
<p>Polypropylene rectangular ducts are square-section ventilation pipes made to order from PP sheet welding, for duct runs where a rectangular profile fits the space or matches equipment connections. They are produced from polypropylene (PP) sheet by bending and hot-melt welding, in standard PP or flame retardant PPs, in beige or grey. Width, height, wall thickness and length are confirmed per project, and sections are supplied in 3 m lengths or in lengths confirmed per project.</p>
<p>Rectangular PP duct is a good fit when a square section suits the installation space, the equipment connection or the building layout. The XICHENG rectangular range is made to order, so dimensions are confirmed against your duct schedule and drawings before manufacture. For round PP duct in standard catalog sizes, see <a href="https://plastic-duct.com/product/polypropylene-round-ducts/">Polypropylene Round Ducts</a>.</p>
<p>A rectangular duct is one part of a ventilation system: it connects to fans, fittings and airflow dampers rather than replacing them, and matching square elbows, flanges, tees and dampers are available from the same supplier, so a complete PP duct line can be specified from one source.</p>
<h2>Product Selection Summary</h2>
<h3>Good Fit</h3>
<ul>
<li>Duct runs where a square or rectangular section fits the space better than a round duct</li>
<li>Laboratory ventilation systems with fume hood, bench or cabinet connections on a square section</li>
<li>Industrial and workshop exhaust where the duct route follows equipment and building lines</li>
<li>Engineering and OEM projects where dimensions are confirmed from drawings before manufacture</li>
</ul>
<h3>Conditions To Confirm</h3>
<ul>
<li>Required width, height, wall thickness, section length and quantity</li>
<li>Material grade: PP or flame retardant PPs (specify grade when fire-rated ductwork is required)</li>
<li>Gas composition, concentration, temperature and moisture at the actual operating point</li>
<li>Color (beige or grey) and connection method (collar or flange) for each joint</li>
<li>Available static pressure and airflow schedule</li>
</ul>
<h3>Not a Replacement For</h3>
<ul>
<li>Fans, airflow balancing devices, room controls or gas treatment equipment</li>
</ul>
<h2>Technical Specifications</h2>
<h3>Confirmed Product Parameters</h3>
<table>
<thead>
<tr>
<th>Parameter</th>
<th>Value</th>
</tr>
</thead>
<tbody>
<tr>
<td>Product Type</td>
<td>Polypropylene Rectangular Air Duct</td>
</tr>
<tr>
<td>Material</td>
<td>PP (polypropylene) or PPs flame retardant grade</td>
</tr>
<tr>
<td>Size Range</td>
<td>Customized &#8211; width × height confirmed per project</td>
</tr>
<tr>
<td>Length</td>
<td>3 m or customized</td>
</tr>
<tr>
<td>Connection Method</td>
<td>Collar / Flange</td>
</tr>
<tr>
<td>Fabrication</td>
<td>PP sheet welding; flange welding reinforcement</td>
</tr>
<tr>
<td>Color</td>
<td>Beige / Grey</td>
</tr>
<tr>
<td>Working Temperature</td>
<td>-15℃ to 80℃</td>
</tr>
<tr>
<td>Chemical Resistance</td>
<td>pH 1-14 (acid and alkali)</td>
</tr>
<tr>
<td>Certification</td>
<td>ISO9001, ISO14001, RoHS</td>
</tr>
</tbody>
</table>
<p>Because rectangular ducts are made to order, width, height, wall thickness and section length are confirmed per project against your duct schedule and drawings &#8211; see Selection Notes below for the information to include with your inquiry.</p>
<h2>Material &amp; Performance</h2>
<p>Rectangular PP ducts are made from polypropylene, a lightweight thermoplastic synthetic resin with strong corrosion resistance, good mechanical strength and excellent weldability &#8211; the weldability is what lets rectangular sections be formed from flat PP sheet. The properties that matter in rectangular ductwork include:</p>
<ul>
<li><strong>Acid and alkali resistance:</strong> PP withstands corrosion by high-concentration acids and alkalis across a wide pH range (pH 1-14), preventing secondary chemical reactions between the medium and the pipe body.</li>
<li><strong>Smooth wall, low flow resistance:</strong> the smooth, uniform wall of the duct gives low flow resistance and resists scaling and deposit buildup.</li>
<li><strong>Sound insulation:</strong> PP reduces vibration and noise caused by air flow in the duct run.</li>
<li><strong>Anti-condensation and low heat loss:</strong> PP is a poor thermal conductor, reducing condensation and heat loss along the run.</li>
<li><strong>Light weight and easy installation:</strong> PP duct is light, easy to install and operate &#8211; an advantage when rectangular sections are handled and joined on site.</li>
<li><strong>Long service life:</strong> PP duct systems offer a service life of up to 50 years under specified operating conditions.</li>
</ul>
<p>Flame retardant PPs is available where fire-rated ductwork is required; specify the required flame retardant grade when inquiring.</p>
<h2>Applications</h2>
<p>Rectangular PP ducts are used wherever a square section is preferred for air movement and corrosive fume handling:</p>
<ul>
<li><strong>Laboratory ventilation</strong>, where square duct connects fume hoods, benches and cabinets &#8211; see <a href="https://plastic-duct.com/product/laboratory-ventilation-system-square-plastic-pipe-air-duct-xicheng/">laboratory ventilation square ducts</a> for the laboratory-specific range.</li>
<li><strong>Industrial and workshop ventilation</strong> for corrosive gas handling, where the rectangular profile follows equipment and building lines.</li>
<li><strong>Chemical and plating process exhaust</strong> where duct routes are fixed by equipment layout.</li>
<li><strong>Retrofit and replacement runs</strong> where an existing rectangular duct size must be matched.</li>
</ul>
<p>PP resists acid and alkali attack (pH 1-14), insulates sound, prevents condensation and stays light and easy to install &#8211; properties that apply equally to rectangular and round sections.</p>
<h2>Selection Notes &amp; Quotation Information</h2>
<h3>Rectangular or Round?</h3>
<p>Round PP duct is generally the lower-cost, lower-flow-resistance option for straight runs, and the XICHENG round range covers standard catalog sizes from φ20 mm to φ500 mm. Rectangular duct is chosen where a square section fits the space or matches equipment connections &#8211; for example under ceilings, against walls, or at laboratory workstations &#8211; and, for the same circumference or cross-section, rectangular sections are generally more expensive than round, depending on wall thickness and outer flange reinforcement. If the installation allows either profile, the round range is usually the more economical choice.</p>
<h3>To Quote a Rectangular PP Duct</h3>
<p>Provide: required width, height, wall thickness, section length and quantity, material grade (PP or flame retardant PPs), color, connection method (collar or flange), application, destination port, and your duct schedule or drawings. Gas composition, temperature and available static pressure help confirm wall thickness and reinforcement for the actual duty.</p>
<p>MOQ and lead time are confirmed per project. <strong>Request a quote</strong> via WhatsApp or email using the contact block below.</p>
<h2>Installation &amp; System Integration</h2>
<p>Rectangular PP ducts are connected with collar or flange joints:</p>
<ul>
<li><strong>Collar connection:</strong> a collar at the section end receives the next section for a stable joint &#8211; fast field installation.</li>
<li><strong>Flange connection:</strong> flanges are welded to the duct and joined with screws &#8211; suited to high-sealing working conditions and allows maintenance disassembly.</li>
</ul>
<p>Sections are produced by PP sheet welding, and flange welding is applied for reinforcement where the duct body needs extra support. Complete systems combine rectangular ducts with matching accessories: <a href="https://plastic-duct.com/product/pp-90-elbow/">PP 90&deg; elbows</a>, square tees, reducers and <a href="https://plastic-duct.com/product/pp-air-duct-flange/">flanges</a>. See the full range of <a href="https://plastic-duct.com/product/">PP duct systems</a>.</p>
<h2>Related Products</h2>
<ul>
<li><a href="https://plastic-duct.com/product/plastic-square-tubing/">Plastic Square Tubing</a></li>
<li><a href="https://plastic-duct.com/product/laboratory-ventilation-system-square-plastic-pipe-air-duct-xicheng/">PP Laboratory Exhaust Duct</a></li>
<li><a href="https://plastic-duct.com/product/polypropylene-round-ducts/">Polypropylene Round Ducts</a></li>
<li><a href="https://plastic-duct.com/product/pp-90-elbow/">PP 90&deg; Duct Elbow</a></li>
<li><a href="https://plastic-duct.com/product/pp-air-duct-flange/">PP Duct Flange</a></li>
<li><a href="https://plastic-duct.com/product/">Full PP Duct Range</a></li>
<li><a href="https://plastic-duct.com/pp-air-duct-guide/">PP Air Duct Guide</a> &#8211; a complete guide to PP duct types, sizes and materials.</li>
</ul>
<h2>FAQ</h2>
<h3>What is a polypropylene rectangular duct?</h3>
<p>A polypropylene (PP) rectangular duct is a square-section ventilation pipe made to order from PP sheet welding. Width, height, wall thickness and length are confirmed per project instead of taken from a catalog.</p>
<h3>What sizes are available?</h3>
<p>Rectangular PP ducts are made to order. Width, height, wall thickness and section length are confirmed per project against your duct schedule and drawings.</p>
<h3>What is the standard length?</h3>
<p>Rectangular PP ducts are supplied in 3 m sections or in lengths confirmed per project.</p>
<h3>Is flame retardant PP available?</h3>
<p>Yes. PPs flame retardant grade is available; specify the required flame retardant grade when inquiring.</p>
<h3>How are rectangular ducts connected?</h3>
<p>Two standard methods are offered: collar connection (a collar at the section end receives the next section) and flange connection (screwed flanges for high-sealing duties).</p>
<h3>Rectangular or round &#8211; which should I choose?</h3>
<p>Round PP duct is usually the more economical choice for straight runs and is available in catalog sizes from φ20 mm to φ500 mm. Rectangular duct suits runs where a square section fits the space or matches equipment connections, and is confirmed to your drawings.</p>
<p><!-- xicheng-engineering-contact:start --></p>
<div class="xicheng-engineering-contact">
<h2>Contact the XICHENG EP Team Today.</h2>
<p class="xicheng-engineering-contact__intro">Send your rectangular PP duct requirements &#8211; width, height, wall thickness, length and quantity, material grade, color, connection method, application, destination and drawings &#8211; and our engineering team will confirm specifications and return a quotation.</p>
<p>📌 <strong>Manufacturing Head Office:</strong> No.34 Zhenxing Road (Shengtaian Heavy Industrial Park B), Loucun, Guangming New Dist, Shenzhen, Guangdong, China</p>
<p>☎️ <strong>Direct Hotline / WhatsApp:</strong> <a href="https://wa.me/8618927456906" target="_blank" rel="noopener">+86 189 2745 6906</a></p>
<p>📬 <strong>Engineering Mailbox:</strong> <a href="mailto:xicheng023@outlook.com">xicheng023@outlook.com</a></p>
</div>
<p><!-- xicheng-engineering-contact:end --></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Polypropylene Round Ducts</title>
		<link>https://plastic-duct.com/product/polypropylene-round-ducts/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=polypropylene-round-ducts</link>
		
		<dc:creator><![CDATA[Corbin – Engineer]]></dc:creator>
		<pubDate>Wed, 15 Mar 2023 01:41:57 +0000</pubDate>
				<guid isPermaLink="false">https://plastic-duct.com/?post_type=product&#038;p=2753</guid>

					<description><![CDATA[<p>This polypropylene (PP) round duct is an injection-molded ventilation pipe for laboratory exhaust, workshop and warehouse ventilation, and general fume extraction. It is available in standard diameters from 20 mm to 500 mm with matched wall thickness, in 3 m or 4 m lengths, with flange, socket or hot-air welding connections.</p>
<ul>
  <li>PP or PPs flame retardant material, working temperature -15℃ to 80℃</li>
  <li>Acid and alkali resistant (pH 1-14), sound-insulating, anti-condensation</li>
  <li>Standard sizes φ20-500 mm; custom diameter, wall thickness and color</li>
  <li>Certified ISO9001, ISO14001, RoHS</li>
  <li>Full matching fittings: elbows, tees, reducers, flanges, dampers</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h2>Product Overview</h2>
<p>Polypropylene round ducts are injection-molded PP ventilation pipes used to move air and low-concentration fumes in laboratories, workshops, warehouses and general exhaust systems. XICHENG supplies them as straight round duct sections from φ20 mm to φ500 mm in standard 3 m or 4 m lengths, with wall thickness matched to each diameter.</p>
<p>Polypropylene (PP) is a lightweight thermoplastic synthetic resin with high chemical resistance and good mechanical strength. Round PP ducts are injection molded to give a smooth internal surface, consistent wall thickness and low flow resistance. They are produced in standard and PPs flame retardant grades, in beige or grey, and support flange, socket or hot-air welding connections.</p>
<p>This round duct family is sold in two standard size groups: φ20-φ90 mm sections for ventilation and drainage duty, and φ110-φ500 mm sections for ventilation duty. Custom diameters, wall thicknesses and lengths are available. Duct sections are one part of a ventilation system: they connect to fans, fittings and dampers rather than replacing them, and the XICHENG range includes matching elbows, tees, reducers, flanges, couplings and airflow dampers so a complete PP duct line can be specified from one supplier.</p>
<h2>Product Selection Summary</h2>
<h3>Good Fit</h3>
<ul>
<li>Laboratory and process exhaust requiring corrosion-resistant rigid ductwork</li>
<li>Workshop and warehouse ventilation at normal temperature conditions</li>
<li>Chemical fume handling where smooth walls reduce pressure loss and deposits</li>
<li>Systems built with flange, socket or hot-air welding joints</li>
</ul>
<h3>Conditions To Confirm</h3>
<ul>
<li>Gas composition, concentration, temperature and moisture at the actual operating point</li>
<li>Diameter, wall thickness and section length per duct run</li>
<li>Connection method (flange, socket, or welding) for each joint</li>
<li>Available static pressure and airflow schedule</li>
<li>Flame retardant grade, when fire-rated ductwork is required</li>
</ul>
<h3>Not a Replacement For</h3>
<ul>
<li>Fans, airflow balancing devices, room controls or treatment equipment</li>
</ul>
<h2>Technical Specifications</h2>
<h3>Confirmed Product Parameters</h3>
<table>
<thead>
<tr>
<th>Parameter</th>
<th>Value</th>
</tr>
</thead>
<tbody>
<tr>
<td>Product Type</td>
<td>Polypropylene Round Ducts (injection molded)</td>
</tr>
<tr>
<td>Material</td>
<td>PP or PPs flame retardant material</td>
</tr>
<tr>
<td>Diameter Range</td>
<td>φ20 mm &#8211; φ500 mm (standard)</td>
</tr>
<tr>
<td>Wall Thickness</td>
<td>2.8 mm &#8211; 5.5 mm (matched to diameter)</td>
</tr>
<tr>
<td>Standard Length</td>
<td>4 m (φ20-φ90), 3 m (φ110-φ500)</td>
</tr>
<tr>
<td>Working Temperature</td>
<td>-15℃ to 80℃</td>
</tr>
<tr>
<td>Color</td>
<td>Beige / Grey</td>
</tr>
<tr>
<td>Connection Method</td>
<td>Flange / Socket / Hot-air welding</td>
</tr>
<tr>
<td>Certification</td>
<td>ISO9001, ISO14001, RoHS</td>
</tr>
</tbody>
</table>
<p><a href="https://plastic-duct.com/wp-content/uploads/2023/03/PPs-pipe-datasheet.pdf">PPs pipe datasheet (PDF)</a></p>
<h2>Available Sizes</h2>
<h3>Standard Size Options</h3>
<table>
<thead>
<tr>
<th>Outer Diameter</th>
<th>Wall Thickness</th>
<th>Weight</th>
<th>Length</th>
<th>Duty</th>
</tr>
</thead>
<tbody>
<tr>
<td>φ20 mm</td>
<td>2.8 mm</td>
<td>0.5 kg</td>
<td>4 m</td>
<td>Ventilation &amp; drainage</td>
</tr>
<tr>
<td>φ25 mm</td>
<td>2.8 mm</td>
<td>0.6 kg</td>
<td>4 m</td>
<td>Ventilation &amp; drainage</td>
</tr>
<tr>
<td>φ32 mm</td>
<td>3.5 mm</td>
<td>1.0 kg</td>
<td>4 m</td>
<td>Ventilation &amp; drainage</td>
</tr>
<tr>
<td>φ40 mm</td>
<td>4.0 mm</td>
<td>1.3 kg</td>
<td>4 m</td>
<td>Ventilation &amp; drainage</td>
</tr>
<tr>
<td>φ50 mm</td>
<td>4.0 mm</td>
<td>1.8 kg</td>
<td>4 m</td>
<td>Ventilation &amp; drainage</td>
</tr>
<tr>
<td>φ63 mm</td>
<td>4.5 mm</td>
<td>3.65 kg</td>
<td>4 m</td>
<td>Ventilation &amp; drainage</td>
</tr>
<tr>
<td>φ75 mm</td>
<td>5.0 mm</td>
<td>4.34 kg</td>
<td>4 m</td>
<td>Ventilation &amp; drainage</td>
</tr>
<tr>
<td>φ90 mm</td>
<td>5.0 mm</td>
<td>5.19 kg</td>
<td>4 m</td>
<td>Ventilation &amp; drainage</td>
</tr>
<tr>
<td>φ110 mm</td>
<td>3.0 mm</td>
<td>2.6 kg</td>
<td>3 m</td>
<td>Ventilation</td>
</tr>
<tr>
<td>φ160 mm</td>
<td>3.0 mm</td>
<td>4.5 kg</td>
<td>3 m</td>
<td>Ventilation</td>
</tr>
<tr>
<td>φ200 mm</td>
<td>3.3 mm</td>
<td>6.0 kg</td>
<td>3 m</td>
<td>Ventilation</td>
</tr>
<tr>
<td>φ250 mm</td>
<td>4.0 mm</td>
<td>9.0 kg</td>
<td>3 m</td>
<td>Ventilation</td>
</tr>
<tr>
<td>φ315 mm</td>
<td>4.2 mm</td>
<td>12.0 kg</td>
<td>3 m</td>
<td>Ventilation</td>
</tr>
<tr>
<td>φ355 mm</td>
<td>4.2 mm</td>
<td>14.4 kg</td>
<td>3 m</td>
<td>Ventilation</td>
</tr>
<tr>
<td>φ400 mm</td>
<td>4.5 mm</td>
<td>16.8 kg</td>
<td>3 m</td>
<td>Ventilation</td>
</tr>
<tr>
<td>φ450 mm</td>
<td>4.8 mm</td>
<td>20.0 kg</td>
<td>3 m</td>
<td>Ventilation</td>
</tr>
<tr>
<td>φ500 mm</td>
<td>5.5 mm</td>
<td>23.5 kg</td>
<td>3 m</td>
<td>Ventilation</td>
</tr>
</tbody>
</table>
<h3>Custom Sizes</h3>
<p>Custom diameters, wall thicknesses and lengths are available for engineering projects. Send your duct schedule and drawings so each section can be confirmed with approved dimensions before manufacture.</p>
<h2>Material &amp; Performance</h2>
<p>PP round duct pipes are corrosion resistant across a wide pH range (pH 1-14), which suits chemical fume and laboratory exhaust applications. The smooth inner wall of the pipe and its fittings gives low flow resistance and reduces scaling, keeping the duct system efficient over time.</p>
<p>Polypropylene offers several properties that matter in ventilation ductwork:</p>
<ul>
<li><strong>Acid and alkali resistance:</strong> PP withstands high-concentration acids and alkalis in a wide temperature range, preventing secondary chemical reactions between the medium and the pipe body.</li>
<li><strong>Wear resistance and no scaling:</strong> the uniform, smooth inner surface lowers flow resistance and resists deposit buildup.</li>
<li><strong>Reduced vibration and noise:</strong> PP has sound insulation performance that dampens vibration and noise caused by air flow.</li>
<li><strong>Anti-freeze cracking:</strong> PP elasticity lets the pipe section expand with frost-heaving liquid without bursting.</li>
<li><strong>Anti-condensation, low heat loss:</strong> PP is a poor thermal conductor, reducing condensation and heat loss along the run.</li>
<li><strong>Light weight and easy installation:</strong> PP pipe is light, easy to install and operate, and has excellent weldability.</li>
<li><strong>Long service life:</strong> PP duct systems offer a service life of up to 50 years under specified operating conditions.</li>
</ul>
<p>PPs flame retardant material is available where fire-rated ductwork is required; specify the required flame retardant grade when inquiring.</p>
<h2>Applications</h2>
<p>Polypropylene round ducts are used wherever ventilation is needed at normal temperature conditions, particularly where media are corrosive:</p>
<ul>
<li><strong>Laboratory ventilation</strong> and fume exhaust ducting</li>
<li><strong>Workshop ventilation</strong> for corrosive gas treatment</li>
<li><strong>Warehouse ventilation</strong> and general air movement</li>
<li><strong>Chemical and plating process exhaust</strong> where pH resistance is required</li>
<li><strong>Daily-life and sanitary exhaust</strong> systems</li>
</ul>
<p>Because PP prevents secondary reactions between the carried medium and the pipe body, it reduces the purification difficulty of industrial waste gas and waste liquid compared with metal ducting in corrosive services.</p>
<h2>Selection Notes &amp; Quotation Information</h2>
<p>To size a polypropylene round duct system, provide the airflow schedule, duct layout, gas composition, concentration, temperature and available static pressure. Industry design practice specifies the required wall thickness and reinforcement under given wind speeds; for industrial exhaust systems with centrifugal fans at the end, reinforcement by external flanges is commonly used.</p>
<p>For a quotation please send: required diameter(s), quantity, section length and wall thickness, application, destination port, and preferred connection method. MOQ and lead time are confirmed per project.</p>
<p><strong>Request a quote</strong> via WhatsApp or email using the contact block below.</p>
<h2>Installation &amp; System Integration</h2>
<p>Round PP ducts are connected with flanges, socket joints or hot-air welding.</p>
<ul>
<li><strong>Socket connection:</strong> a PP sleeve is welded at the end of each duct section so the next section inserts for a stable joint &#8211; fast field installation.</li>
<li><strong>Flange connection:</strong> PP flanges are welded at both ends and joined with screws &#8211; suited to high-strength, high-sealing working conditions and allows maintenance disassembly.</li>
<li><strong>Hot-air welding:</strong> creates a continuous sealed line where a monolithic run is preferred.</li>
</ul>
<p>In industrial exhaust systems with a centrifugal fan at the end, the fan creates negative pressure inside the duct; reinforcement by external flanges is a common practice. For example, a 3-meter duct is typically reinforced with 2 flanges. Large square duct runs use external flange reinforcement plus internal PP circular pipe for structural support.</p>
<p>XICHENG supplies the matching range to complete the system: <a href="https://plastic-duct.com/product/pp-90-elbow/">PP 90° elbows</a>, <a href="https://plastic-duct.com/product/pp-air-duct-flange/">flanges</a>, <a href="https://plastic-duct.com/product/pp-air-duct-coupling/">couplings</a>, tees, reducers and <a href="https://plastic-duct.com/product/pp-back-draft-damper/">back draft dampers</a>. See the full range of <a href="https://plastic-duct.com/product/">PP duct systems</a>.</p>
<h2>Related Products</h2>
<ul>
<li><a href="https://plastic-duct.com/product/polypropylene-pp-air-duct/">PP Air Duct</a></li>
<li><a href="https://plastic-duct.com/product/pp-plastic-exhaust-duct/">PP Exhaust Duct</a></li>
<li><a href="https://plastic-duct.com/product/custom-pp-round-duct/">Custom PP Round Duct</a></li>
<li><a href="https://plastic-duct.com/product/flame-retardant-pp-duct/">Flame Retardant PP Duct</a></li>
<li><a href="https://plastic-duct.com/pp-air-duct-guide/">PP Air Duct Guide</a> &#8211; a complete guide to PP duct types, sizes and materials.</li>
</ul>
<h2>FAQ</h2>
<h3>What sizes are available?</h3>
<p>Standard round duct sections run from φ20 mm to φ500 mm, in 4 m lengths for φ20-φ90 mm and 3 m lengths for φ110-φ500 mm. Custom diameters and wall thicknesses are available on request.</p>
<h3>Can the duct be customized?</h3>
<p>Yes. Custom diameter, wall thickness, length and color can be confirmed per project based on your duct schedule and drawings.</p>
<h3>Is flame retardant PP available?</h3>
<p>Yes. PPs flame retardant material is available; specify the required flame retardant grade when inquiring.</p>
<h3>What is the working temperature range?</h3>
<p>The working temperature is -15℃ to 80℃. Material grade affects the exact limits, so confirm your operating temperature with the order.</p>
<h3>How are round duct sections connected?</h3>
<p>Three methods are available: socket joints (a sleeve welded at the section end for fast insertion), flange connections (screw-locked PP flanges for high-sealing duties), and hot-air welding for continuous sealed runs.</p>
<h3>What is the typical service life?</h3>
<p>PP duct systems offer a service life of up to 50 years under specified operating conditions.</p>
<p><!-- xicheng-engineering-contact:start --></p>
<div class="xicheng-engineering-contact">
<h2>Contact the XICHENG EP Team Today.</h2>
<p class="xicheng-engineering-contact__intro">Send your round duct requirements &#8211; diameter, quantity, length and wall thickness, application, destination and preferred connection method &#8211; and our engineering team will confirm specifications and return a quotation.</p>
<p>📌 <strong>Manufacturing Head Office:</strong> No.34 Zhenxing Road (Shengtaian Heavy Industrial Park B), Loucun, Guangming New Dist, Shenzhen, Guangdong, China</p>
<p>☎️ <strong>Direct Hotline / WhatsApp:</strong> <a href="https://wa.me/8618927456906" target="_blank" rel="noopener">+86 189 2745 6906</a></p>
<p>📬 <strong>Engineering Mailbox:</strong> <a href="mailto:xicheng023@outlook.com">xicheng023@outlook.com</a></p>
</div>
<p><!-- xicheng-engineering-contact:end --></p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>